Instrument: | double wavelength, automatic wavelength selection, direct reading colorimeter |
Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
Wavelength Accuracy: | ± 1 nm |
Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
Photometric Resolution: | 0.01 A |
Power Supply: | 4 x AA Batteries Lifetime: approximately 53 hours or 15,000 tests |
Auto-Off: | automatic switch-off |
Display: | LCD (back-light upon keypress) |
Storage: | internal ring memory for 16 data sets |
Interface: | Infrared interface for data transfer |
Time: | Real time and date |
Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
Dimensions: | 190 x 110 x 55 mm |
Weight: | 455 grams (including batteries) |
Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
Compliance: | CE |
Includes: | Instrument in carrying case 4 Micro batteries (AA) 3 Round vials (Glass) with lids Liquid Reagents for each parameter Guarantee sheet Certificate (COC) Instruction manual |
ຄຳອະທິບາຍ
Lovibond® MD 200 Colorimeter, 3 In 1, Chlorine, pH, Cyanuric Acid
Test | Test Range |
Chlorine | 0.02 – 4.0 mg/l |
pH Value | 6.5-8.4 |
Cyanuric Acid | 0 – 160 mg/l |
Designed to meet the latest technical requirements, the MD 200 photometer can be used in practically every area of water analysis. The high-precision optics with its top-quality interference filters uses long-term stable LEDs as light-source. Because there are no moving parts, the entire measurement device requires absolutely no maintenance. Precise and reproducible analysis results are obtained in a short time. The units impress with their user-friendliness, ergonomic design, compact dimensions and easy handling. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a guaranteed minimum 5 or 10 year shelf life or using liquid reagents.
Scroll Memory (SM)
To avoid unnecessary scrolling for the required test method, the instrument memorizes the last method used before switching off the instrument. When the instrument is switched on again, the scroll list comes up with the last used test method first.
Zero Setting (OTZ)
For certain versions of the instrument it is not necessary to zero the instrument each time. The zero setting is held in memory until the device is turned off. (One Time Zero – OTZ). The zero setting can be confirmed whenever it is usefull.
Data Transfer (IRiM)