Price 1.778$ excl.VAT

In Stock
Brand: SKU: 2892602 Category:

Description

Optics
LEDs, interference filters (IF) and photo sensor in transparent sample chamber.
Depending on the version, up to 3 different interference filters are used.
Wavelength specifications of interference filters:
430 nm Δ λ = 5 nm
530 nm Δ λ = 5 nm
560 nm Δ λ = 5 nm
580 nm Δ λ = 5 nm
610 nm Δ λ = 6 nm
660 nm Δ λ = 5 nm
Wavelength Accuracy ± 1 nm
Photometric Accuracy 3% FS (T = 20°C – 25°C)
Photometric Resolution: 0.01 mg/l
Power Supply: 4 AA batteries, capacity approx. 53 hours or 15000 tests (without backlight)
Auto – OFF
automatic switch-off
Display
backlit LCD (on keypress)
Storage: internal ring memory for 16 data sets
Interfaces: Infrared interface for test data transfer
Additional feature: real time clock and date
Calibration: factory calibration and user calibration. Reset to factory calibration possible
Dimensions: 190 x 110 x 55 mm (L x W x H)
Weight: basic unit approx. 455 g
Environmental conditions: Temperature: 5 – 40 °C rel. humidity: 30 -90% (non condensing)
Conformity: CE; tested with standard solutions

The RD125 Thermoreactor is a 24 position heating block for reacting Lovibond® Vario tube test vials before the measurement in a photometer. Capable of heating at 100, 120 and 150°C, and with variable time settings for 30, 60 and 120 minutes, the RD125 photometer can be used for the following methods
COD
TOC
Total Chromium
Total Nitrogen
Total Phosphate
After the desired heating period, the unit has an alarm function and will automatically cool down. The unit can also be set for continuous heating for measurement throughout the day.

Optics
LEDs, interference filters (IF) and photo sensor in transparent sample chamber.
Depending on the version, up to 3 different interference filters are used.
Wavelength specifications of interference filters:
430 nm Δ λ = 5 nm
530 nm Δ λ = 5 nm
560 nm Δ λ = 5 nm
580 nm Δ λ = 5 nm
610 nm Δ λ = 6 nm
660 nm Δ λ = 5 nm
Wavelength Accuracy ± 1 nm
Photometric Accuracy 3% FS (T = 20°C – 25°C)
Photometric Resolution: 0.01 mg/l
Power Supply: 4 AA batteries, capacity approx. 53 hours or 15000 tests (without backlight)
Auto – OFF
automatic switch-off
Display
backlit LCD (on keypress)
Storage: internal ring memory for 16 data sets
Interfaces: Infrared interface for test data transfer
Additional feature: real time clock and date
Calibration: factory calibration and user calibration. Reset to factory calibration possible
Dimensions: 190 x 110 x 55 mm (L x W x H)
Weight: basic unit approx. 455 g
Environmental conditions: Temperature: 5 – 40 °C rel. humidity: 30 -90% (non condensing)
Conformity: CE; tested with standard solutions

COD-LR (No.2420720) 750000 kip

COD-MR Middle rang (No.2420721)

COD-HRHigh rang (No.2420722)