In StockProduct Description ET6 Series
Cabinet Temperature range +2 to +40 ° C
Controlled by the system Microprocessor
Indoor temperature display cabinet 0.1 ° C
2 sets of ventilator for better ventilation.
4 connectors
* Can choose the capacity of 180, 260, 360 and 500 liters.
Brand name Lovibond, Germany
ET 618-4, Type 180 3 metal racks + 1 bottom grid I. (approx.): 515 D x 443 W x 700 H mm Net capacity: approx. 140 l A. D. (approx.): 600 D x 600 W x 885 H mm Weight: approx. 39.0 kg Order code: 2 42 82 00
ET 626-5 Type 260 4 metal racks + 1 bottom grid I. (approx.): 515 D x 415 W x 1045 H mm Net capacity: approx. 195 l A. (approx.): 600 D x 600 W x 1216 H mm Weight: approx.49.0 kg Order code: 2 42 82 20
ET 636-6, Type 360 5 metal racks + 1 bottom grid I. (approx.): 515 D x 415 W x 1450 H mm Net capacity: approx. 280 l A. D. (approx.): 600 D x 600 W x 1590 H mm Weight: approx. 64.5 kg Order code: 2 42 82 30 ET 650-8,
Type 500 5 metal racks + 1 bottom grid I. (approx.): 652 D x 515 W x 1300 H mm Net capacity: approx. 395 l A. (approx.): 752 D x 710 W x 1516 H mm
Weight: approx. 79.5 kg Order code: 2 42 82 40
| SKU | ET6 Series – Standard Door |
|---|---|
| Dimension | 0 |
| Weight | 0.0000 |
| Manufacturer | Lovibond |
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |