- Recent add item(s)
-
Lovibond MD600 MultiDirect 1 × 1.948$×
- ×
-
Lovibond SpectroDirect Photometer 1 × 4.000$×
ລວມຍ່ອຍ: 10.171$
ລວມຍ່ອຍ: 10.171$
ລາຄາ 94$ ບໍ່ລວມອາກອນ
ມີຢູ່ໃນສາງRange : 0.00 to 3.00 ppm NH3-N
Resolution : 0.01 ppm
Measurement Method : Colormetric
Accuracy (@25°C/77°F) : ±0.05ppm ± 5% of reading
Light Source : Photodiode @470 nm
Light detector : Silicon photocell
The all new HI 700 Checker Ammonia LR for fresh water can be used in place of HI 3824 or HI 38049 fresh water test kits. The Checker®HC is a simple, accurate, and cost effective way to measure low ranges of ammonia in fresh water. Designed as a more accurate alternative to chemical test kits, the HI 700 provides quick, accurate results in four easy steps.
The HI 700 uses an adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method. The reaction between ammonia and reagents causes a yellow tint in the sample.
PRIMARY APPLICATIONS: * Water Quality * Education * Freshwater Aquariums * Wastewater * Environmental
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
The compact TB 210 IR (formerly the TurbiCheck infrared) turbidity meter is designed to allow fast, precise on site or laboratory measurements. The unit measures scattered light at 90 ° angle as stipulated in ISO 7027.
Measuring in the range 0-1100 NTU, the unit is suitable for various applications including drinking water, waste water, process and pool water testing. The infrared light source allows for measurement of coloured and colourless samples.
A simple keypad layout and range selection button ensures further ease of use. Up to 16 results can be stored and reviewed with time and date. The instrument is supplied in a robust carry case with all necessary accessories, and a set of calibration standards.
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No