ມີຢູ່ໃນສາງRange : 0.00 to 3.00 ppm NH3-N
Resolution : 0.01 ppm
Measurement Method : Colormetric
Accuracy (@25°C/77°F) : ±0.05ppm ± 5% of reading
Light Source : Photodiode @470 nm
Light detector : Silicon photocell
The all new HI 700 Checker Ammonia LR for fresh water can be used in place of HI 3824 or HI 38049 fresh water test kits. The Checker®HC is a simple, accurate, and cost effective way to measure low ranges of ammonia in fresh water. Designed as a more accurate alternative to chemical test kits, the HI 700 provides quick, accurate results in four easy steps.
The HI 700 uses an adaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method. The reaction between ammonia and reagents causes a yellow tint in the sample.
PRIMARY APPLICATIONS: * Water Quality * Education * Freshwater Aquariums * Wastewater * Environmental
Product Type: Turbidity Products and Accessories
Brand: Tintometer
ProductLine: Lovibond
Range: (0.1, 20, 200, 800 NTU)
Product Type: Test KitBrand: TintometerProduct Line: LovibondClass: CHECKIT Comparator Test KitGrade: Chlorine (DPD)Range: 0 – 2 mg/l Cl2Increments: 0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.1, 1.2, 1.3, 1.4, 1.6, 1.8, 2.0Accuracy: ±5% (Full Scale)Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manual
Product Type: Incubator
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
| SKU | TC-445S |
|---|---|
| Dimension | 750 x 730 x 1640mm |
| Weight | 78500.0000 |
| Manufacturer | Lovibond |