- Recent add item(s)
-
MD100 Chlorine Meter 3 in 1 1 × 1.084$×
- ×
-
Pipette MPA-20 1 × 625$×
-
Lovibond MultiDirect 1 × 2.334$×
Subtotal: 4.488$
Subtotal: 4.488$
Price 94$ excl.VAT
In StockProduct information “HI705 Checker HC ® – Silica, LR”
The HI 705 Checker®HC is a simple, accurate, and cost effective way to measure low ranges of silica. Designed as a more accurate alternative to chemical test kits, the HI 705 provides quick, accurate results in four easy steps.
The HI 705 uses an adaptation of the ASTM D859 method of heteropoly blue method. The reaction between silica and reagents causes a blue tint in the sample.
PRIMARY APPLICATIONS:* Water Quality * Education * Environmental * Water Treatment (Boilers/Cooling Towers)
Order Information: The HI 705 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (1 bottle reagent A, 6 packets of reagent B, and 6 packets of reagent C), 1 x 1.5V AAA battery, and an instruction manual.
Range : 0.00 to 2.00 ppm
Resolution : 0.01 ppm
Accuracy (@25°C/77°F) : ±0.03ppm ± 5% of reading
Measurement Method : Colorimetric
Light Source : Photodiode @610 nm
Method : Adaptation of the ASTM D859 method of heteropoly blue method
Light Detector : Silicon photocell
Power Supply : Auto off after 10 min. of inactivity
Environment : Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions : 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight : 64 g (2.25 oz.)
Product Type: Turbidity Products and Accessories
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |