In StockProduct information “HI711 Checker HC ® – Total Chlorine”
The HANNA HI 711 Checker® HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give 5 to 10 points resolution while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI?711 Checker®HC is accurate and affordable.
This Checker®HC portable handheld colorimeter features a resolution of 0.01 ppm and ±0.03 ppm (mg/L) ±3% of reading accuracy. It also uses an EPA approved DPD method.
The contoured style of the Checker®HC fits in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.
The HI 711 Checker®HC is extremely simple to use. First, zero the instrument with your water sample. Next, add the reagent. Last, place the vial into the Checker®HC, press the button and read the results. It’s that easy.
Range : 0.00 to 3.50 ppm (mg/L)
Resolution : 0.01 ppm (mg/L)
Accuracy @ 25°C : ±0.03 ppm ±3% of reading
Light Source : LED @ 525 nm
Light Detector : Silicon photocell
Environment : 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type : (1) 1.5V AAA
Auto-off : after two minutes of non-use and ten seconds after reading
Dimensions : 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight : 64 g (2.25 oz.)
Method : adaptation of USEPA method 330.5, DPD method
Product Type: Turbidity Products and Accessories
Display | Graphic Display | ||
Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
Wavelength Accuracy | ± 1nm | ||
Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
Photometric Resolution | 0.005 A | ||
Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
Auto Off | approx 20 minutes after last keypress with audible signal | ||
Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
Unit Weight | 450g | ||
Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
Memory Capacity | 1000 data sets with time, date, sample ID | ||
Conformity | CE |
The LovibondR MultiDirect is a microprocessor controlled photometer with ergonomically designed keypad, large graphic display and waterproof sample chamber and casing. It can operate as a bench top photometer using mains power, and is supplied with rechargeable batteries for portable use. With 6 LED light sources the Multi Direct can measure at peak absorbances for many different methods, ensuring result accuracy and reliability for many applications.