- Recent add item(s)
- ×
-
MD100 Chlorine Meter 3 in 1 1 × 1.223$×
-
Lovibond MD600 MultiDirect 1 × 1.887$×
- ×
-
Lovibond® UV-VIS Spectrophotometer 1 × 1.887$×
Subtotal: 6.990$
Subtotal: 6.990$
Price 0$ excl.VAT
In StockThe HI 715 Checker®HC is a simple, accurate, and cost effective way to measure medium ranges of ammonia in fresh water. Designed as a more accurate alternative to chemical test kits, the HI 715 provides quick, accurate results in four easy steps.
The HI 715 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Order Information: The HI 715 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (1 bottle of HI 715A-0 and 1 bottle of HI 715B-0), 1 x 1.5V AAA battery, and an instruction manual.
Range : 0.00 to 9.99 ppm NH3-N
Resolution : 0.01 ppm
Accuracy (@20°C/68°F) : ±0.05ppm ±5% of reading
Measurement Method : Colorimetric
Light Source : Photodiode @470 nm
Light Detector : Silicon photocell
Method : Adaptation of the ASTM Manual of Water and Environmental
Technology, D1426-93, Nessler method. The reaction between ammonia and
reagents causes a yellow tint in the sample.
Power Supply Battery – 1 x 1.5V AAA
Power Auto Off After 10 min. of inactivity
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
Highlights
– Multi-Parameter Testing device combines all of the key water testing parameters and testing ranges
– Portable instrument for use in the lab, plant or out in the field
– User interface is intuitive and easy to navigate
The MD 600 multi-parameter photometer is pre-programmed with over 120 water testing parameters and ranges. Featuring a rugged, waterproof design, this instrument is the ideal testing solution for a variety of applications and industries.
Applications
– Boiler Water Cooling Water Disinfection Control Drinking Water Treatment Galvanization Pool Water Control Pool Water Treatment Raw Water Treatment Waste Water Treatment
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
Product Type:Colorimeter
Brand:Tintometer
Product Line:Lovibond