In StockThe HI 715 Checker®HC is a simple, accurate, and cost effective way to measure medium ranges of ammonia in fresh water. Designed as a more accurate alternative to chemical test kits, the HI 715 provides quick, accurate results in four easy steps.
The HI 715 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Order Information: The HI 715 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (1 bottle of HI 715A-0 and 1 bottle of HI 715B-0), 1 x 1.5V AAA battery, and an instruction manual.
Range : 0.00 to 9.99 ppm NH3-N
Resolution : 0.01 ppm
Accuracy (@20°C/68°F) : ±0.05ppm ±5% of reading
Measurement Method : Colorimetric
Light Source : Photodiode @470 nm
Light Detector : Silicon photocell
Method : Adaptation of the ASTM Manual of Water and Environmental
Technology, D1426-93, Nessler method. The reaction between ammonia and
reagents causes a yellow tint in the sample.
Power Supply Battery – 1 x 1.5V AAA
Power Auto Off After 10 min. of inactivity
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
Product Type: Incubator
SKU RE-511052BT
Dimension 0
Weight 0.0000
Manufacturer Lovibond
Measurement Range 0.01 – 6 mg/L
Other Function No
Sensor Output Interface No
Power Supply No Need
Resolution No
Water resistance No
Data logger N/A
Accuracy No
| SKU | TC-445S |
|---|---|
| Dimension | 750 x 730 x 1640mm |
| Weight | 78500.0000 |
| Manufacturer | Lovibond |
| 220 to 240V | |
| ±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) | |
| 600mm | |
| 2 to 40°C, steps of 0.1°C | |
| CE | |
| 441 x 513 x 702mm | |
| LED | |
| 0.1°C |
| 50Hz | |
| 702mm | |
| 39kg | |
| 2 to 40 °C | |
| 135L | |
| 220 to 240V, 50 Hz | |
| 4 internal sockets | |
| 600mm |
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||