- Recent add item(s)
- ×
-
Lovibond TB-210IR Turbidity Meter 1 × 1.000$×
-
Lovibond MD600 MultiDirect 1 × 1.948$×
- ×
ລວມຍ່ອຍ: 5.104$
ລວມຍ່ອຍ: 5.104$
ລາຄາ 90$ ບໍ່ລວມອາກອນ
ມີຢູ່ໃນສາງAmmonia
Ammonia Range 0.0 to 99.9 ppm as NH₄⁺
Ammonia Resolution 0.1 ppm
Ammonia Accuracy ±1.0 ppm ±5% of reading
Ammonia Method adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
General Meter
Automatic Shut-Off after ten minutes of non-use
Battery Type/Life (1) 1.5V AAA
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5mm x 61mm x 37.5mm (3.2″ x 2.4″ x 1.5”)
Weight 64 g (2.25 oz.)
Photometer/Colorimeter Light Source LED @ 470 nm
Photometer/Colorimeter Light Detector silicon photocell
Ordering Information HI733 Checker® is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI733A-0 and 1 bottle of HI733B-0), battery, instructions and quick start guide.
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
Product Type: Incubator
The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No