In StockRange: 0 to 500 ppm
Resolution: 1 ppm
Accuracy: (@25°C/77°F) ±3 ppm ± 5% of reading
Measurement Method: Colorimetric
Light Source Photodiode: @525 nm
Light Detector: Silicon photocell
Method: Adaptation of the standard methods for water and wastewater 4500Cl.
Power Supply: Battery – 1 x 1.5V AAA
Power Auto Off: After 10 min. of inactivity
Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions: 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Dimensions: 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight: 64 g (2.25 oz.)
The HI 771 Checker®HC is a simple, accurate, and cost effective way to measure ultra-high ranges of chlorine. Designed as a more accurate alternative to chemical test kits, the HI 771 provides quick, accurate results in four easy steps.
1.) Step One – Add a sample to the included cuvette(s)
2.) Step Two – Insert sample into the Checker and zero it out
3.) Step Three – Remove sample and add reagent
4.) Step Four – Reinsert sample and click the button to measure your results or… – Press and hold the button for 3 seconds for a time reaction reading
The HI 771 uses an adaptation of the standard methods for water and wastewater 4500Cl.
Range: 0 to 500 ppm
Resolution: 1 ppm
Accuracy: (@25°C/77°F) ±3 ppm ± 5% of reading
Measurement Method: Colorimetric
Light Source Photodiode: @525 nm
Light Detector: Silicon photocell
Method: Adaptation of the standard methods for water and wastewater 4500Cl.
Power: Supply Battery – 1 x 1.5V AAA
Power Auto Off: After 10 min. of inactivity
Environment: 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions: 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Dimensions: 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight: 64 g (2.25 oz.)
Highlights
– Multi-Parameter Testing device combines all of the key water testing parameters and testing ranges
– Portable instrument for use in the lab, plant or out in the field
– User interface is intuitive and easy to navigate
The MD 600 multi-parameter photometer is pre-programmed with over 120 water testing parameters and ranges. Featuring a rugged, waterproof design, this instrument is the ideal testing solution for a variety of applications and industries.
Applications
– Boiler Water Cooling Water Disinfection Control Drinking Water Treatment Galvanization Pool Water Control Pool Water Treatment Raw Water Treatment Waste Water Treatment
| SKU | TC-445S |
|---|---|
| Dimension | 750 x 730 x 1640mm |
| Weight | 78500.0000 |
| Manufacturer | Lovibond |
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |