ມີຢູ່ໃນສາງThe HI 96714 meter measures the cyanide concentration in waters. The meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.
Cyanide is a pollutant that originates mostly from metalurgicaland galvanic industrial plants. Cyanide is poisonous to human nervous system, and it is therefore imperative to monitor and control its level in potable water. Continuous monitoring in waste effluents is required, and cyanide is removed using alkaline chlorination procedure. Due to this, European norm limit the concentration of cyanide in drinking water to 0.05 mg/L, while the EPA has established that the maximum level is not to exceed 0.2 mg/L.
Ammonia
Ammonia Range 0.0 to 99.9 ppm as NH₄⁺
Ammonia Resolution 0.1 ppm
Ammonia Accuracy ±1.0 ppm ±5% of reading
Ammonia Method adaptation of the ASTM Manual of Water and Environmental Technology D1426-92, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.
General Meter
Automatic Shut-Off after ten minutes of non-use
Battery Type/Life (1) 1.5V AAA
Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions 81.5mm x 61mm x 37.5mm (3.2″ x 2.4″ x 1.5”)
Weight 64 g (2.25 oz.)
Photometer/Colorimeter Light Source LED @ 470 nm
Photometer/Colorimeter Light Detector silicon photocell
Ordering Information HI733 Checker® is supplied with (2) sample cuvettes with caps, ammonia reagent starter kit for 25 tests (1 bottle of HI733A-0 and 1 bottle of HI733B-0), battery, instructions and quick start guide.
Range : 0.00 to 3.00 ppm NH3-N
Resolution : 0.01 ppm
Measurement Method : Colormetric
Accuracy (@25°C/77°F) : ±0.05ppm ± 5% of reading
Light Source : Photodiode @470 nm
Light detector : Silicon photocell
Range : 0.00 to 2.50 ppm (mg/L)
Resolution : 0.01 ppm (mg/L)
Accuracy @ 25°C : ±0.03 ppm ±3% of reading
Light Source : LED @ 525 nm
Light Detector : Silicon photocell
Environment : 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type : (1) 1.5V AAA
Auto-off : after two minutes of non-use and ten seconds after reading
Dimensions : 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight : 64 g (2.25 oz.)
Method : adaptation of USEPA method 330.5, DPD method