- Recent add item(s)
- ×
-
MD100 Chlorine Meter 3 in 1 1 × 1.084$×
- ×
-
MD100 Chlorine Meter 3 in 1 1 × 1.223$×
Subtotal: 9.975$
Subtotal: 9.975$
Price 0$ excl.VAT
In StockDie neuen digitalen Handrefraktometer von HANNA instruments wurden speziell für die Anforderungen der Weinbranche entwickelt. Sie verbinden Einfachheit mit Leistungsstärke. Basierend auf dem Prinzip der refraktiven Indexmessung bestimmen sie einfach und schnell den Zuckergehalt von Trauben und Most. Die automatische Technik garantiert präzise und wiederholbare Messergebnisse, während das tragbare, leichte Gehäuse für einen bequemen Einsatz vor Ort sorgt.
| 220 to 240V | |
| ±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) | |
| 600mm | |
| 2 to 40°C, steps of 0.1°C | |
| CE | |
| 441 x 513 x 702mm | |
| LED | |
| 0.1°C |
| 50Hz | |
| 702mm | |
| 39kg | |
| 2 to 40 °C | |
| 135L | |
| 220 to 240V, 50 Hz | |
| 4 internal sockets | |
| 600mm |
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No


