6% Off

Price 17.350.000$ excl.VATSale 16.350.000$ excl.VAT

In Stock
Brand: SKU: HI98172 Categories: ,

Description

Product information “HI98172 ISE/pH/ORP/°C Meter with CalCheck”

  • pH Calibration Check™
  • Five point pH calibration with seven standard and five custom pH buffers
  • Log on demand (500 samples)
  • User-selectable “calibration time out”
  • Tutorial messages on LCD
  • PC interface via USB

 

  • HI 98172 is a pH/ORP/ISE meter housed in a waterproof casing. Up to five point pH calibration is available with seven memorized pH buffers and five custom pH buffers to provide users with the flexibility necessary to adjust the calibration range to obtain the most accurate and precise readings.
  • Exchange out the pH sensor for an ORP sensor to obtain mV readings. ISE sensors are calibrated up to five points and measurements are displayed in ppm.
  • Calibration Check™ incorporates an electrode condition graph which alerts the user with regards to the electrode status. If readings are taken too far outside the calibration range, the unit will warn the user with a graphic signal. Users may set a reminder to notify when calibration is due.
  • HI 98172 features tutorial messages on the LCD and an auto-end mode to ensure readings are taken only when they are stable. Comprehensive GLP data are directly accessible by pressing the GLP key and log-on-demand holds up to 500 records. Data can be transferred to a PC via USB with optional HI 92000 software and HI 920014 USB connection cable.

Specification :

Range pH -4.0 to 20.0 pH; -4.00 to 20.00 pH
mV ±699.9; ±2000 mV
ISE 0.001 to 19990 ppm
Temperature -20.0 to 120.0°C (-4.0 to 248.0°F)
Resolution pH 0.1 pH; 0.01 pH
mV 0.1 mV (±699.9 mV); 1 mV (±2000)
ISE 0.001 ppm (0.001 to 1.999); 0.01 ppm (2.00 to 19.99); 0.1 ppm (20.0 to 199.9); 1 ppm (200 to 1999); 10 ppm (2000 to 19990)
Temperature 0.1°C (0.1°F)
Accuracy (@20°C/68ºF) pH ±0.1 pH; ±0.01 pH
mV ±0.2 mV (±699.9 mV); ±1 mV (±2000 mV)
ISE ±0.5% f.s.
Temperature ±0.2°C (±0.4°F) excluding probe error
pH Calibration up to five point calibration with seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and 5 custom buffers
ISE Calibration up to five point calibration with six standard buffers available (0.1, 1, 10, 100, 1000, 10000 ppm)
Slope/Offset Calibration ±1 pH/from 80 to 110%
Rel. mV Offset Range ±2000 mV
Temperature Compensation manual or automatic from –20.0 to 120.0 ºC (–4.0 to 248.0 ºF)
pH Electrode HI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)
Temperature Probe HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)
Logging log on demand, 500 samples
PC Connection opto-isolated USB with optional HI 92000 software
Input Impedance 1012 Ohms
Power supply 1.5V AAA (3) / approximately 200 hours of continuous use without backlight (50 hours with backlight). User selectable auto-off (5, 10, 20, 60 minutes or can be disabled)
Environment 0 to 50°C (32 to 122°F); RH max 100%
Dimensions / Weight 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) / 300 g (10.6 oz.)