9% Off

Price 12.454.000$ excl.VATSale 11.457.000$ excl.VAT

In Stock
Brand: SKU: HI98192 Categories: ,

Description

Product information “HI98192 Waterproof Portable EC/TDS/Resistivity/Salinity Meter”

The HI98192 is supplied with the HI763133 four-ring conductivity probe with a built in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.

HI98192 has an expanded conductivity range from 0.000 μS/cm to 1000 mS/cm actual conductivity (400 mS/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.

HI98192 can be used to perform all three stages of USPmethod required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.

Choose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.

    EC and TDS measurements are fully customizable and include:

  • Cell constant selection between 0.0 and 10.000
  • Selection of linear or non-linear (natural water), or
  • No temperature compensation

The temperature compensation coefficient range is configurable from 0.00 to 10.00%/°C with a choice of reference temperatures of 15°C, 20°C and 25°C. The conductivity to TDS factor is adjustable from 0.40 and 1.00.

The HI98192 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.

The log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.

GLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.

Access help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.

The compact, durable HI720192 carry case is thermoformed to hold all necessary components for taking a field measurement, including: the meter, probe, beakers and conductivity standards.

EC Range : 0.000 to 9.999 μS/cm*; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm (actual conductivity; temperature compensated :  to 400 mS/cm)
EC Resolution : 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
EC Accuracy : ±1% of reading (±0.01 μS/cm or 1 digit, whichever is greater)
EC Calibration : automatic up to five points with seven memorized standards (0.00 μS/cm, 84.0 μS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm)
TDS Range : 0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g/L); 10.00 to 99.99 ppt (g/L); 100.0 to 400.0 ppt (g/L)
TDS Resolution : 0.01 ppm; 0.1 ppm; 0.001 ppt (g/L); 0.01 ppt (g/L); 0.1 ppt (g/L)
TDS Accuracy : ±1% of reading (±0.05 mg/L (ppm) or 1 digit, whichever is greater)
Resistivity Range : 1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution : 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm*
Resistivity Accuracy : ±1% of reading (±10 Ω or 1 digit, whichever is greater)
Salinity Range : % NaCl : 0.0 to 400.0%; practical salinity: 0.00 to 42.00 (PSU); natural seawater scale – UNESCO 1966: 0.00 to 80.00 (ppt)
Salinity Resolution : 0.1%; 0.01
Salinity Accuracy : ±1% of reading
Salinity Calibration : max. one point only in % range (with HI7037 standard); use conductivity calibration : for all other ranges
Temperature Range : -20.0 to 120.0°C (-4.0 to 248.0°F)
Temperature Resolution : 0.1°C (0.1°F)
Temperature Accuracy : ±0.2°C; ±0.4°F (excluding probe error)
Temperature Calibration : one or two points
Temperature Compensation :  noTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear – ISO/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)
Measurement Modes : autorange, autoend, lock and fixed range
Reference Temperature : 15°C, 20°C and 25°C
Temperature Coefficient : 0.00 to 10.00 %/°C
TDS Factor : 0.40 to 1.00
Electrode/Probe : HI763133, four ring conductivity/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included)
Log-on-demand : 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)
Memorized Profiles : up to 10
PC Connectivity : opto-isolated USB with optional HI 92000 software and micro USB cable
Battery Type/Life : 1.5V AA batteries (4) / approximately 100 hours of continuous use (without backlight), 25 hours with backlight
Auto-off user selectable: 5, 10, 30, 60 min or can be disabled
Environment : 0 to 50°C (32 to 122°F); RH 100% (IP67)
Dimensions : 185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)
Weight : 400 g (14.2 oz.)
Ordering Information : HI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 μS/cm calibration : solution (230 mL), HI7035M 111.8 mS/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case.
Notes *The 0.001 μS/cm EC range and 0.1 MΩ•cm not available with supplied probe