- Recent add item(s)
-
Lovibond MD600 MultiDirect 1 × 1.887$×
- ×
- ×
Subtotal: 4.043$
Price 117$ excl.VAT
In StockDiST ® 2 is one of the “classics” among the conductivity or “total dissolved solids” testers. The tester is easy to use, fast and accurate, and is therefore ideally suited for routine measurements. He has a robust probe of non-oxidizable graphite and an integrated temperature sensor for temperature compensated readings.
Specification:
Measuring range : 0 to 10.00 g / L (ppt)
Resolution : 0.01 g / L (ppt)
Accuracy : ± 2% of full scale calibration
Manual, at 1 point
Temperature Compensation Automatic from 0 to 50 ° C
Power supply : 4 x 1.5 V batteries / approx 200 hours
Dimensions : 175 x 41 x 23 mm Weight 95 g
Product Type: Test KitBrand: TintometerProduct Line: LovibondClass: CHECKIT Comparator Test KitGrade: Chlorine (DPD)Range: 0 – 2 mg/l Cl2Increments: 0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.1, 1.2, 1.3, 1.4, 1.6, 1.8, 2.0Accuracy: ±5% (Full Scale)Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manual
Product Type: Pool & Spa Products (Photometers)Brand: TintometerProduct Line: LovibondInterface: InfraredPower Supply: Four AA BatteriesHolds: approx. 1000 data setsIncludes: Carrying CaseOverall Dimensions: 210 x 95 x 45 mm (unit); 395 x 295 x 106 mm (case)
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
220 to 240V | |
±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) | |
600mm | |
2 to 40°C, steps of 0.1°C | |
CE | |
441 x 513 x 702mm | |
LED | |
0.1°C |
50Hz | |
702mm | |
39kg | |
2 to 40 °C | |
135L | |
220 to 240V, 50 Hz | |
4 internal sockets | |
600mm |
Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
Wavelength Accuracy: | ± 1 nm |
Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
Photometric Resolution: | 0.01 A |
Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
Auto-Off: | 10 minutes after last keypress |
Display: | LCD (back-light upon keypress) |
Storage: | automatic; 16 data sets with time and date stamp |
Interface: | Infrared interface for data transfer |
Time: | Real time and date |
Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
Dimensions: | 155 x 75 x 35 mm |
Weight: | 250 grams (including batteries) |
Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
Compliance: | CE |
Warranty: | 2 years |
Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |