In StockThis indicator from HANNA has a large backlit LCD to give users instantaneous readings of both pH and temperature that can be easily read in dim light. The HI 991401-02 provides automatic calibration, automatic buffer selection and automatic temperature compensation.
HI 991401-02’s waterproof housing has been designed to meet the growers’ need for an indictor that is well suited to withstand the aggressive environments found in agricultural and hydroponics applications. Measurements are highly accurate and can be verified with one or two point calibrations. With a 12 VDC power supply included with the meter, low battery failures are never an issue.
The pH electrode has been specially designed to address the needs of growers. It’s design guarantees greater clogging resistance in fertilizer solutions with high concentrations of phosphate, nitrate, etc. to ensure longer electrode life.
Specification :
| Range | pH | 0.0 to 14.0 pH |
| Temperature | 0.0 to 60.0°C (32 to 140°F) | |
| Resolution | pH | 0.1 pH |
| Temperature | 0.1°C (0.1°F) | |
| Accuracy | pH | ±0.1 pH |
| Temperature | ±0.5°C (±1°F) | |
| Probes | HI 1293D PEI body, pre-amplified pH electrode with 1/2” NPT pipe thread, DIN connector and 2 m (6.6’) cable (included); HI 1294 temperature probe with 1.2” NPT pipe thread and 2 m (6.6’) cable (fixed) | |
| pH Calibration | automatic, 1 or 2 points with 2 sets of memorized buffers (pH 4.01 / 7.01 / 10.01 or pH 4.01 / 6.86 / 9.18) | |
| Temperature Compensation | Automatic | |
| Input Impedance | 1012 Ohm | |
| Power Supply | 12 Vdc power adapter (included) | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% | |
| Dimensions | 160 x 105 x 31 mm (6.3 x 4.1 x 1.2) | |
| Weight | 190 g (6.7 oz.) – meter only |
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
Product Type:Colorimeter
Brand:Tintometer
Product Line:Lovibond
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |