- Recent add item(s)
- ×
- ×
-
HI9812-5 MULTIPARAMETER PH/EC/TDS/°C - EC TO1990 ΜS/CM 1 × 3.136.000$×
- ×
Subtotal: 3.138.066$
Price 234$ excl.VAT
In StockWaterproof and chemically resistant, HI 993301 has been designed to meet the grower’s need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. At startup, HI 993301-02 performs a self-check to ensure proper working condition.
This monitor from HANNA has a backlit LCD and displays instantaneous readings of both EC or TDS and temperature—even from a distance.
This instrument features a stability indicator that prompts the user when to take the reading. For manual recording purposes, readings can be frozen on the LCD display by pressing the HOLD button.
Calibration and temperature compensation are automatic, while the EC/TDS conversion factor and temperature coefficient factor (β) are user adjustable for application specific measurements.
Specification :
| Range | EC | 0 to 3999 µS/cm |
| TDS | 0 to 2000 ppm | |
| Temperature | 0.0 to 60.0°C (32 to 140°F) | |
| Resolution | EC | 1 µS/cm |
| TDS | 1 ppm | |
| Temperature | 0.1°C (0.1°F) | |
| Accuracy | EC | ±2% F.S. |
| TDS | ±2% F.S. | |
| Temperature | ±0.5°C (±1°F) | |
| EC/TDS Calibration | automatic, 1 point, at 1413 µS/cm | |
| Probe | HI 7630 (included) | |
| TDS Conversion Factor | adjustable from 0.0 to 1.00 | |
| Temperature Compensation | Automatic with ß adjustable from 0.0 to 2.4%/°C | |
| Power Supply | 12 Vdc power adapter (included) | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% | |
| Dimensions | 160 x 105 x 31 mm (6.3 x 4.1 x 1.2″) | |
| Weight | 190 g (6.7 oz.) – meter only |
Product Type: Turbidity Products and Accessories
Brand: Tintometer
ProductLine: Lovibond
Range: (0.1, 20, 200, 800 NTU)
| 220 to 240V | |
| ±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) | |
| 600mm | |
| 2 to 40°C, steps of 0.1°C | |
| CE | |
| 441 x 513 x 702mm | |
| LED | |
| 0.1°C |
| 50Hz | |
| 702mm | |
| 39kg | |
| 2 to 40 °C | |
| 135L | |
| 220 to 240V, 50 Hz | |
| 4 internal sockets | |
| 600mm |
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |