- Recent add item(s)
-
Lovibond MD600 MultiDirect 2 × 1.948$×
-
Lovibond PM600 Pool Photometer 1 × 1.612$×
-
Lovibond MD600 MultiDirect 1 × 1.887$×
- ×
Subtotal: 7.840$
Subtotal: 7.840$
Price 234$ excl.VAT
In StockWaterproof and chemically resistant, HI 993301 has been designed to meet the grower’s need for equipment suited to the aggressive environments found in agricultural and hydroponics applications. At startup, HI 993301-02 performs a self-check to ensure proper working condition.
This monitor from HANNA has a backlit LCD and displays instantaneous readings of both EC or TDS and temperature—even from a distance.
This instrument features a stability indicator that prompts the user when to take the reading. For manual recording purposes, readings can be frozen on the LCD display by pressing the HOLD button.
Calibration and temperature compensation are automatic, while the EC/TDS conversion factor and temperature coefficient factor (β) are user adjustable for application specific measurements.
Specification :
| Range | EC | 0 to 3999 µS/cm |
| TDS | 0 to 2000 ppm | |
| Temperature | 0.0 to 60.0°C (32 to 140°F) | |
| Resolution | EC | 1 µS/cm |
| TDS | 1 ppm | |
| Temperature | 0.1°C (0.1°F) | |
| Accuracy | EC | ±2% F.S. |
| TDS | ±2% F.S. | |
| Temperature | ±0.5°C (±1°F) | |
| EC/TDS Calibration | automatic, 1 point, at 1413 µS/cm | |
| Probe | HI 7630 (included) | |
| TDS Conversion Factor | adjustable from 0.0 to 1.00 | |
| Temperature Compensation | Automatic with ß adjustable from 0.0 to 2.4%/°C | |
| Power Supply | 12 Vdc power adapter (included) | |
| Environment | 0 to 50°C (32 to 122°F); RH max 95% | |
| Dimensions | 160 x 105 x 31 mm (6.3 x 4.1 x 1.2″) | |
| Weight | 190 g (6.7 oz.) – meter only |
Product Type: Turbidity Products and Accessories
Brand: Tintometer
ProductLine: Lovibond
Range: (0.1, 20, 200, 800 NTU)
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
Product Type: Test Kit
Brand: Tintometer
Product Line: Lovibond
Class: CHECKIT Comparator Test Kit
Grade: Chlorine (DPD)
Range: 0 – 4 mg/l Cl2
Increments: 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0, 2.5, 3.0, 3.5, 4.0
Accuracy: ±5% (Full Scale)
Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manual


