ມີຢູ່ໃນສາງGeneral Specifications HI801 iris
Wavelength Range 340-900 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ±1.5 nm
Photometric Range 0.000-3.000 Abs
Photometric Accuracy 5 mAbs at 0.000-0.500 Abs; 1% at 0.500-3.000 Abs
Measurement Mode transmittance (%), absorbance and concentration
Sample Cell 10 mm square, 50 mm rectangular, 16 mm round, 22 mm round, 13 mm round (vial)
Wavelength Selection automatic, based on the selected method (editable for user methods only)
Light Source tungsten halogen lamp
Optical System split beam
Wavelength Calibration internal, automatic at power-on with visual feedback
Stray Light <0.1 % T at 340 nm with NaNO₂
Spectral Bandwidth 5 nm
Number of Methods 150 Factory / 100 User
Data Points Stored 9999 measured values
Export Capability csv file format, pdf file format
Connectivity 1x USB A (mass storage host); 1x USB B (mass storage device)
Battery Life 3000 measurements or 8 hours
Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH
Dimensions 155 x 205 x 322 mm (6.1 x 8.0 x 12.6″)
Weight 3 kg (6.6 Ibs.)
Highlights
– Multi-Parameter Testing device combines all of the key water testing parameters and testing ranges
– Portable instrument for use in the lab, plant or out in the field
– User interface is intuitive and easy to navigate
The MD 600 multi-parameter photometer is pre-programmed with over 120 water testing parameters and ranges. Featuring a rugged, waterproof design, this instrument is the ideal testing solution for a variety of applications and industries.
Applications
– Boiler Water Cooling Water Disinfection Control Drinking Water Treatment Galvanization Pool Water Control Pool Water Treatment Raw Water Treatment Waste Water Treatment
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
Product Type: Pool & Spa Products (Photometers)Brand: TintometerProduct Line: LovibondInterface: InfraredPower Supply: Four AA BatteriesHolds: approx. 1000 data setsIncludes: Carrying CaseOverall Dimensions: 210 x 95 x 45 mm (unit); 395 x 295 x 106 mm (case)
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
Product Type: Turbidity Products and Accessories
Brand: Tintometer
ProductLine: Lovibond
Range: (0.1, 20, 200, 800 NTU)