- Recent add item(s)
- ×
-
Lovibond MD600 MultiDirect 1 × 1.887$×
- ×
-
Lovibond PM600 Pool Photometer 1 × 1.612$×
ລວມຍ່ອຍ: 3.707$
ລວມຍ່ອຍ: 3.707$
ລາຄາ 5.040$ ບໍ່ລວມອາກອນ
ມີຢູ່ໃນສາງGeneral Specifications HI801 iris
Wavelength Range 340-900 nm
Wavelength Resolution 1 nm
Wavelength Accuracy ±1.5 nm
Photometric Range 0.000-3.000 Abs
Photometric Accuracy 5 mAbs at 0.000-0.500 Abs; 1% at 0.500-3.000 Abs
Measurement Mode transmittance (%), absorbance and concentration
Sample Cell 10 mm square, 50 mm rectangular, 16 mm round, 22 mm round, 13 mm round (vial)
Wavelength Selection automatic, based on the selected method (editable for user methods only)
Light Source tungsten halogen lamp
Optical System split beam
Wavelength Calibration internal, automatic at power-on with visual feedback
Stray Light <0.1 % T at 340 nm with NaNO₂
Spectral Bandwidth 5 nm
Number of Methods 150 Factory / 100 User
Data Points Stored 9999 measured values
Export Capability csv file format, pdf file format
Connectivity 1x USB A (mass storage host); 1x USB B (mass storage device)
Battery Life 3000 measurements or 8 hours
Power Supply 15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery
Environment 0 to 50 °C (32 to 122 °F); 0 to 95% RH
Dimensions 155 x 205 x 322 mm (6.1 x 8.0 x 12.6″)
Weight 3 kg (6.6 Ibs.)
Product Type: Turbidity Products and Accessories
Brand: Tintometer
ProductLine: Lovibond
Range: (0.1, 20, 200, 800 NTU)
The LovibondR MultiDirect is a microprocessor controlled photometer with ergonomically designed keypad, large graphic display and waterproof sample chamber and casing. It can operate as a bench top photometer using mains power, and is supplied with rechargeable batteries for portable use. With 6 LED light sources the Multi Direct can measure at peak absorbances for many different methods, ensuring result accuracy and reliability for many applications.
SKU RE-511052BT
Dimension 0
Weight 0.0000
Manufacturer Lovibond
Measurement Range 0.01 – 6 mg/L
Other Function No
Sensor Output Interface No
Power Supply No Need
Resolution No
Water resistance No
Data logger N/A
Accuracy No
| 220 to 240V | |
| ±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) | |
| 600mm | |
| 2 to 40°C, steps of 0.1°C | |
| CE | |
| 441 x 513 x 702mm | |
| LED | |
| 0.1°C |
| 50Hz | |
| 702mm | |
| 39kg | |
| 2 to 40 °C | |
| 135L | |
| 220 to 240V, 50 Hz | |
| 4 internal sockets | |
| 600mm |
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |