MD100 Chlorine Meter 3 in 1
Price 1.223$ excl.VAT
In StockInstrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
Wavelength Accuracy: | ± 1 nm |
Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
Photometric Resolution: | 0.01 A |
Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
Auto-Off: | 10 minutes after last keypress |
Display: | LCD (back-light upon keypress) |
Storage: | automatic; 16 data sets with time and date stamp |
Interface: | Infrared interface for data transfer |
Time: | Real time and date |
Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
Dimensions: | 155 x 75 x 35 mm |
Weight: | 250 grams (including batteries) |
Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
Compliance: | CE |
Warranty: | 2 years |
Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
Description
Lovibond® MD 100 Chlorine, pH, and Cyanuric Acid 3 in 1 Colorimeter, with 0.01 – 6.0 mg/l Cl2 DPD, 6.5 – 8.4 pH and 0 – 160 mg/l Cyanuric Acid Reagents (each)
AquaPRO3 Photometer – CL, pH, CYA
The MD 100 uses high quality interference filters with long-life LEDs as a light source without any moving parts in a transparent sample chamber. The units supply accurate, reproducible results very quickly. Other major advantages include ease of operation, ergonomic design, compact dimensions and safe handling.
The calibration and software-based adjustment options mean that the MD 100 is also suitable for use as a testing instrument. The tests are conducted using either Lovibond® tablet reagents with long-term stability and a guaranteed minimum 5 or 10 year shelf life, VARIO powder reagents or using liquid reage
Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
Wavelength Accuracy: | ± 1 nm |
Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
Photometric Resolution: | 0.01 A |
Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
Auto-Off: | 10 minutes after last keypress |
Display: | LCD (back-light upon keypress) |
Storage: | automatic; 16 data sets with time and date stamp |
Interface: | Infrared interface for data transfer |
Time: | Real time and date |
Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
Dimensions: | 155 x 75 x 35 mm |
Weight: | 250 grams (including batteries) |
Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
Compliance: | CE |
Warranty: | 2 years |
Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
Related Products
-
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : NoPrice 78$ excl.VAT -
Product Type: Test Kit
Brand: Tintometer
Product Line: Lovibond
Class: CHECKIT Comparator Test Kit
Grade: Chlorine (DPD)
Range: 0 – 4 mg/l Cl2
Increments: 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0, 2.5, 3.0, 3.5, 4.0
Accuracy: ±5% (Full Scale)
Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manualPrice 189$ excl.VAT -
-
Digestion Required:YesEPA compliant:YesInstrument:All except DR/820, PC IIMethod:8000Method Name:Reactor DigestionNumber of tests:150Parameter:Chemical Oxygen DemandQuantity:150 /pkRange:3 – 150 mg/L CODPrice 100$ excl.VAT
-
SKU TC-445S Dimension 750 x 730 x 1640mm Weight 78500.0000 Manufacturer Lovibond Price 3.445$ excl.VAT -
Price 3.409.000$ excl.VATSale 3.136.000$ excl.VAT