Price 2.389$ excl.VAT

In Stock

HI83300 is a compact, multiparameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves.

Description

General Specifications for all Models
Measurement Channels 5 x optical channels; 1 x digital electrode channel (pH measurement)
Absorbance
Range 0.000 to 4.000 Abs
Resolution 0.001 Abs
Accuracy ±0.003 Abs (at 1.000 Abs)
Light Source light-emitting diode
Bandpass Filter Bandwidth 8 nm
Bandpass Filter
Wavelength Accuracy ± 1.0 nm
Light Detector silicon photocell
Cuvette Type round, 24.6 mm diameter and 16 mm diameter
Number of Methods 128 max
pH
Range -2.00 to 16.00 pH (±1000 mV)*
Resolution 0.01 pH (0.1 mV)
Temperature Compensation Automatic (-5.0 to 100.0°C; 23.0 to 212.0°F)*
Temperature Range -20 to 120°C (-4.0 to 248.0 °F)
Resolution 0.1 °C (0.1 °F)
Additional
Specifications
Logging 1000 readings (mixed photometer and electrode)
Display 128 x 64 pixel B/W LCD with backlight
USB-A (Host) Functions mass–storage host
USB-B (Device) Functions power input, mass-storage device
Battery Life > 500 photometer measurements, or 50 hours of continuous pH measurement
Power Supply 5 VDC USB 2.0 power adapter / type micro-B connector
3.7 VDC Li-polymer rechargeable battery, non-serviceable
Environment 0 to 50°C (32 to 122°F); 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)
Weight 1.0 kg (2.2 lbs.)

General Specifications for all Models
Measurement Channels 5 x optical channels; 1 x digital electrode channel (pH measurement)
Absorbance
Range 0.000 to 4.000 Abs
Resolution 0.001 Abs
Accuracy ±0.003 Abs (at 1.000 Abs)
Light Source light-emitting diode
Bandpass Filter Bandwidth 8 nm
Bandpass Filter
Wavelength Accuracy ± 1.0 nm
Light Detector silicon photocell
Cuvette Type round, 24.6 mm diameter and 16 mm diameter
Number of Methods 128 max
pH
Range -2.00 to 16.00 pH (±1000 mV)*
Resolution 0.01 pH (0.1 mV)
Temperature Compensation Automatic (-5.0 to 100.0°C; 23.0 to 212.0°F)*
Temperature Range -20 to 120°C (-4.0 to 248.0 °F)
Resolution 0.1 °C (0.1 °F)
Additional
Specifications
Logging 1000 readings (mixed photometer and electrode)
Display 128 x 64 pixel B/W LCD with backlight
USB-A (Host) Functions mass–storage host
USB-B (Device) Functions power input, mass-storage device
Battery Life > 500 photometer measurements, or 50 hours of continuous pH measurement
Power Supply 5 VDC USB 2.0 power adapter / type micro-B connector
3.7 VDC Li-polymer rechargeable battery, non-serviceable
Environment 0 to 50°C (32 to 122°F); 0 to 95% RH, non-condensing
Dimensions 206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)
Weight 1.0 kg (2.2 lbs.)