- Recent add item(s)
-
Lovibond TC-135S Thermostatically Controlled Incubators with Standard Door (for BOD-OxiDirect) 1 × 3.445$×
- ×
- ×
Subtotal: 8.113$
Subtotal: 8.113$
Price 2.194.000$ excl.VATSale 2.018.000$ excl.VAT
Preamplified pH and EC Probe with CAL CHECK™ for use with HI 9813 Series. Recommended for greenhouses, hydroponics, environmental monitoring, water treatment, boilers and cooling towers.
Reference : Single, Ag/AgCl
Junction : Cloth
Plug DIN : with CAL CHECK™
Electrolyte : Gel
Max Pressure : 0.1 bar
Range : pH: 0 to 13 / EC T: 20 to 40°C (68 to 104°F)
Tip Shape : Spheric (dia: 8 mm)
Temperature Sensor : Yes
Amplifier : Yes
Body Material : Polypropylene
Cable : 7-pole; 2 m (6.6′)
Recommended : Use Greenhouses, hydroponics, environmental monitoring, water treatment, boiles, cooling towers
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
Product Type: Test Kit
Brand: Tintometer
Product Line: Lovibond
Class: CHECKIT Comparator Test Kit
Grade: Chlorine (DPD)
Range: 0 – 4 mg/l Cl2
Increments: 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0, 2.5, 3.0, 3.5, 4.0
Accuracy: ±5% (Full Scale)
Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manual
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
Product Type: Pool & Spa Products (Photometers)Brand: TintometerProduct Line: LovibondInterface: InfraredPower Supply: Four AA BatteriesHolds: approx. 1000 data setsIncludes: Carrying CaseOverall Dimensions: 210 x 95 x 45 mm (unit); 395 x 295 x 106 mm (case)
The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.