Pour/Cloud Point Testers MPC-102S
Price 0$ excl.VAT
In StockPP: ASTM D6749, ASTM D97, ISO 3016
CP: ASTM D7683, ASTM D2500, ISO 3015
- Bench top, 1 position with a cryo block bath
- +51°C to -65°C
- VFD
Description
TANAKA’s MPC series has been designed for automatic determination of POUR POINT (PP) and CLOUD POINT (CP) with small specimen size and shorter test cycle time while securing better test precision than the conventional manual methods.
PP measurement is by “AIR PRESSURE METHOD” (ASTM D6749), and CP measurement is by “SMALL TEST JAR METHOD” (ASTM D7683).
The epoch-making automatic PP test method yields 1°C test resolution, while the new CP method yields 0.1°C resolution.
Test Methods | PP: ASTM D6749, ASTM D97, ISO 3016 CP: ASTM D7683, ASTM D2500, ISO 3015 |
---|---|
Type | Bench top, 1 position with a cryo block bath |
Measuring range | +51°C to -65°C |
Display | VFD |
Ext. port | RS-232C |
Size | 300W × 460D × 320H, 222W × 407D × 238H (CB-80C) |
Weight | 11kg + 13kg (CB-80C) |
Power cons. | 50W + 150W (CB-80C) |
Ultra Low Temp Without Liquid Chiller
With a cryo block bath, model CB-80C manufactured by SCINICS®, MPC-102S works without an external liquid chiller.
Compact Design & Energy Efficient
A compact and energy efficient cryo block bath model CB-80C is capable of cooling the samples to -65°C without a liquid chiller. Electricity consumption is only 20% comparing to MPC-102L with external liquid chiller.
Principle of Pour Point Detection

Related Products
-
Model: MPC-102A/MPC-102L
PP: ASTM D6749, ASTM D97, ISO 3016 / CP: ASTM D7683, ASTM D2500, ISO 3015
- Bench top, 1poshion, with air cooled Peltier cooler/Bench top, 1position, with liquid cooled Peltier cooler
- +51 to -25°C in 25°C ambient/+51 to -65°C when used with 1set of TCU-40B chiller (opt)
- VFD module
Price 0$ excl.VAT -
-
Model: ACR-M3
- ISO 10370, ASTM D4530, etc.
- Up to 500°C
- automatically regulated, and displayed on the front panel
Price 0$ excl.VAT -
Model atg-8
ASTM D56, IP 304, JIS K2265-1
- ambient to +95°C for atg-8w
-20°C to +95°C for atg-8l (with an optional chiller) - Gas flame or Electric Coil
- PT-100 in stainless steel sheath
- CRC Thermocoupl
- 10°C to 35°C
- 500W (atg-8w), 250W (atg-8l)
Price 0$ excl.VAT - ambient to +95°C for atg-8w
-
ISO 2592, ASTM D92, IP36, JIS K-2265-4
- Ambient to 400°C
- Gas flame with 2 pilot electric coils
- PT-100 in stainless steel sheath
- Double Ionization rings
Price 0$ excl.VAT -
Model:
- ISO 2977, ASTM D611, etc.
- transparent or opaque / dark (< 8.0 on ASTM color scale) petroleum products
- ambient to 170°C (338°F), below RT with optional jacketed cell and external chiller.
- modified U-tube
- by photo-electric detector
Price 0$ excl.VAT