- Recent add item(s)
-
Lovibond MultiDirect 1 × 2.334$×
- ×
- ×
- ×
-
MD100 Chlorine Meter 3 in 1 1 × 1.084$×
Subtotal: 3.652$
Subtotal: 3.652$
Price 0$ excl.VAT
In StockpH Electrode for field applications. Recommended for use with HI 98140, HI 98150, HI 98230 and HI 98240 pH meters.[p[
Reference : single, Ag/AgCl
Junction/Flow Rate : cloth
Electrolyte : gel
Max Pressure : 2 bar
Range : pH: 0 to 13
Recommended Operating Temp. : 20 to 40°C (68 to 104°F)
Tip/Shape : spheric (dia: 5 mm)
Temperature Sensor : yes
Amplifier : yes
Body Material : PEI
Cable : 7-pole; 1 m (3.3′)
Connection : 7-pin DIN
SKU RE-511052BT
Dimension 0
Weight 0.0000
Manufacturer Lovibond
Measurement Range 0.01 – 6 mg/L
Other Function No
Sensor Output Interface No
Power Supply No Need
Resolution No
Water resistance No
Data logger N/A
Accuracy No
Display | Graphic Display | ||
Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
Wavelength Accuracy | ± 1nm | ||
Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
Photometric Resolution | 0.005 A | ||
Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
Auto Off | approx 20 minutes after last keypress with audible signal | ||
Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
Unit Weight | 450g | ||
Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
Memory Capacity | 1000 data sets with time, date, sample ID | ||
Conformity | CE |
Product Type: Turbidity Products and Accessories
The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.