In StockProduct information “HI705 Checker HC ® – Silica, LR”
The HI 705 Checker®HC is a simple, accurate, and cost effective way to measure low ranges of silica. Designed as a more accurate alternative to chemical test kits, the HI 705 provides quick, accurate results in four easy steps.
The HI 705 uses an adaptation of the ASTM D859 method of heteropoly blue method. The reaction between silica and reagents causes a blue tint in the sample.
PRIMARY APPLICATIONS:* Water Quality * Education * Environmental * Water Treatment (Boilers/Cooling Towers)
Order Information: The HI 705 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (1 bottle reagent A, 6 packets of reagent B, and 6 packets of reagent C), 1 x 1.5V AAA battery, and an instruction manual.
Range : 0.00 to 2.00 ppm
Resolution : 0.01 ppm
Accuracy (@25°C/77°F) : ±0.03ppm ± 5% of reading
Measurement Method : Colorimetric
Light Source : Photodiode @610 nm
Method : Adaptation of the ASTM D859 method of heteropoly blue method
Light Detector : Silicon photocell
Power Supply : Auto off after 10 min. of inactivity
Environment : Environment 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions : 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight : 64 g (2.25 oz.)
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |
| SKU | TC-445S |
|---|---|
| Dimension | 750 x 730 x 1640mm |
| Weight | 78500.0000 |
| Manufacturer | Lovibond |
The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.