- Recent add item(s)
- ×
-
HI143 - TEMPERATURE LOGGER 1 × 0$×
- ×
Subtotal: 445$
Price 94$ excl.VAT
In StockProduct information “HI707 Checker HC ® – Nitrite, LR”
The HI 707 Checker®HC is a simple, accurate, and cost effective way to measure low ranges of nitrite. Designed as a more accurate alternative to chemical test kits, the HI 707 provides quick, accurate results in four easy steps.
The HI 707 uses an adaptation of EPA diazotization method 354.1. The reaction between nitrite and the reagent causes a pink tint in the sample.
Order Information: The HI 707 Checker®HC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of nitrite LR reagent), 1 x 1.5V AAA battery, and an instruction manual.
Range : 0 to 600 ppb NO2 -N
Resolution : 1 ppb
Accuracy (@25°C/77°F) : ±20 ppb ± 5% of reading
Measurement Method : Colorimetric
Light Source : Photodiode @470 nm
Light Detector : Silicon photocell
Method : Adaptation of EPA diazotization method 354.1. The reaction between nitrite and the reagent causes a pink tint in the sample.
Power Supply : 1 x 1.5V AAA battery
Power Auto Off : After 10 min. of inactivity
Environment : 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions : 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight : 64 g (2.25 oz.)
The LovibondR MultiDirect is a microprocessor controlled photometer with ergonomically designed keypad, large graphic display and waterproof sample chamber and casing. It can operate as a bench top photometer using mains power, and is supplied with rechargeable batteries for portable use. With 6 LED light sources the Multi Direct can measure at peak absorbances for many different methods, ensuring result accuracy and reliability for many applications.
Display | Graphic Display | ||
Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
Wavelength Accuracy | ± 1nm | ||
Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
Photometric Resolution | 0.005 A | ||
Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
Auto Off | approx 20 minutes after last keypress with audible signal | ||
Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
Unit Weight | 450g | ||
Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
Memory Capacity | 1000 data sets with time, date, sample ID | ||
Conformity | CE |
Product Type: Incubator
SKU RE-511052BT
Dimension 0
Weight 0.0000
Manufacturer Lovibond
Measurement Range 0.01 – 6 mg/L
Other Function No
Sensor Output Interface No
Power Supply No Need
Resolution No
Water resistance No
Data logger N/A
Accuracy No
Product Type:Colorimeter
Brand:Tintometer
Product Line:Lovibond