- Recent add item(s)
- ×
- ×
- ×
-
Lovibond SpectroDirect Photometer 1 × 4.000$×
- ×
- ×
- ×
-
MD100 Chlorine Meter 3 in 1 1 × 1.084$×
Subtotal: 5.499$
Price 94$ excl.VAT
In StockProduct information “HI713 Checker HC ® – Phosphate, LR”
Orthophosphates are found in natural and wastewaters. They are commonly added to drinking water as a corrosion inhibitor. The instantaneous analysis of orthophosphate by colorimetric determination provides rapid results using a standard analysis technique.
The HANNA HI 713 Checker®HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give only a few resolution points while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 713 Checker®HC is accurate and affordable.
The HI 713 Checker®HC portable handheld colorimeter features a resolution of 0.01 ppm (250 points) and ±0.04 ppm (mg/L) ±4% of reading accuracy. The HI 713 Checker®HC uses an adaptation of Standard Method 4500-P E, Ascorbic Acid method.
The HI 713 Checker®HC is extremely simple to use. First, zero the instrument with your water sample. Next, add the reagents. Last, place the vial into the Checker®HC, press the button and read the results. It’s that easy.
Range : 0.00 to 2.50 ppm (mg/L)
Resolution : 0.01 ppm (mg/L)
Accuracy @ 25°C : ±0.04 ppm (mg/L) ±4% of reading
Light Source : LED @ 525 nm
Light Detector : silicon photocell
Environment : 0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type : (1) 1.5V AAA
Auto-off : after two minutes of non-use and ten seconds after reading
Dimensions : 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight : 64 g (2.25 oz.)
Method : adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method
Highlights
– Multi-Parameter Testing device combines all of the key water testing parameters and testing ranges
– Portable instrument for use in the lab, plant or out in the field
– User interface is intuitive and easy to navigate
The MD 600 multi-parameter photometer is pre-programmed with over 120 water testing parameters and ranges. Featuring a rugged, waterproof design, this instrument is the ideal testing solution for a variety of applications and industries.
Applications
– Boiler Water Cooling Water Disinfection Control Drinking Water Treatment Galvanization Pool Water Control Pool Water Treatment Raw Water Treatment Waste Water Treatment
Product Type: Turbidity Products and Accessories
Brand: Tintometer
ProductLine: Lovibond
Range: (0.1, 20, 200, 800 NTU)
Product Type: Test KitBrand: TintometerProduct Line: LovibondClass: CHECKIT Comparator Test KitGrade: Chlorine (DPD)Range: 0 – 2 mg/l Cl2Increments: 0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.1, 1.2, 1.3, 1.4, 1.6, 1.8, 2.0Accuracy: ±5% (Full Scale)Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manual
Product Type: Turbidity Products and Accessories
| Display | Graphic Display | ||
| Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
| Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
| Wavelength Accuracy | ± 1nm | ||
| Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
| Photometric Resolution | 0.005 A | ||
| Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
| Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
| Auto Off | approx 20 minutes after last keypress with audible signal | ||
| Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
| Unit Weight | 450g | ||
| Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
| Memory Capacity | 1000 data sets with time, date, sample ID | ||
| Conformity | CE |