Simulate output to discover malfunctions. Great tools for trouble-shooting your existing pH/ORP meter or process instruments.
Provided with universal BNC connector
Sometimes it is difficult to recognize whether a particular malfunction is due to the meter or the electrode. By simply connecting HI 931001 to your meter’s input socket and turning the dials, pH readings can be simulated from 0 to 14 pH in 0.01 steps. The output signals all correspond to pH values at 25°C and your pH meter should be able to check the span of your pH meter.
For the mV range, HI 931001 can simulate output from -1000 to +1000 mV in 1 mV steps.
ange pH : 0.00 to 14.00 pH
ORP : -1000 to 1000
Resolution pH : 0.01 pH
ORP : 1 mV
Accuracy : @ 20°C pH ±0.01 pH
ORP : ±1 mV
Temperature
Compensation all output values are simulated at 25°C
Battery Type / Life : 9V / approximately 500 hours of use
Environment : 0 to 50°C (32 to 122°F); RH max 95%
Dimensions : 185 x 82 x 53 mm (7.3 x 3.2 x 2.1’’)
Weight : 320 g (11.3 oz.)
Display | Graphic Display | ||
Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
Wavelength Accuracy | ± 1nm | ||
Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
Photometric Resolution | 0.005 A | ||
Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
Auto Off | approx 20 minutes after last keypress with audible signal | ||
Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
Unit Weight | 450g | ||
Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
Memory Capacity | 1000 data sets with time, date, sample ID | ||
Conformity | CE |
Product Type: Test Kit
Brand: Tintometer
Product Line: Lovibond
Class: CHECKIT Comparator Test Kit
Grade: Chlorine (DPD)
Range: 0 – 4 mg/l Cl2
Increments: 0, 0.2, 0.4, 0.6, 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0, 2.5, 3.0, 3.5, 4.0
Accuracy: ±5% (Full Scale)
Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manual