In StockHI 981406-02 has been specially designed for water treatment and swimming pool applications where both pH and ORP need to be monitored. Instead of sourcing two meters, users can now continuously measure both pH and ORP with HI 981406-02.
There are two separate adjustable set points for pH and ORP. Once the pH set point is exceeded, the appropriate LED light will come on to alert the operator. Likewise, once the ORP level drops below the set point, the red ORP light will stay on.
HI 981406-02 is supplied with HI 1283 ground probe. The HI 1283 ground probe provides users with more reliable readouts by suppressing current effects, which are found in pools. The optional HI 2114P/2 pH electrode and HI 3214P/2 ORP electrode are designed specifically for swimming pools. Both probes are constructed with a specially designed fiber salt-bridge making each particularly resistant to clogging in pools.
Specification :
Range : pH 0.0 to 14.0 pH
Range : mV -999 to 999 mV
Resolution : pH 0.1 pH
Resolution : mV 1 mV
Accuracy : pH ±0.2 pH
Accuracy : mV ±5 mV
pH Calibration : manual, 1 or 2 points
Setpoint : pH: adjustable from 5.0 to 9.0 pH; ORP: adjustable from 350 to 850 mV
Alarm : 2 LED’s (1 for pH and 1 for ORP) light up when: pH value > setpoint and/or ORP value < setpoint
Probe : HI 2114P/2 replaceable pH electrode (not included) HI 3214P/2 replaceable ORP electrode (not included); HI 1283 potential matching pin with 2 m (6.6') cable (included)
Input Impedance : 1012 Ohm
Power Supply : 12 Vdc power adapter (included)
Environment : 0 to 50°C (32 to 122°F); RH max 95%
Dimensions : 165 x 110 x 35 mm (6.4 x 4.3 x 1.4")
Weight : 300 g (10.6 oz.)
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
Product Type: Turbidity Products and Accessories
Brand: Tintometer
ProductLine: Lovibond
Range: (0.1, 20, 200, 800 NTU)
Highlights
– Multi-Parameter Testing device combines all of the key water testing parameters and testing ranges
– Portable instrument for use in the lab, plant or out in the field
– User interface is intuitive and easy to navigate
The MD 600 multi-parameter photometer is pre-programmed with over 120 water testing parameters and ranges. Featuring a rugged, waterproof design, this instrument is the ideal testing solution for a variety of applications and industries.
Applications
– Boiler Water Cooling Water Disinfection Control Drinking Water Treatment Galvanization Pool Water Control Pool Water Treatment Raw Water Treatment Waste Water Treatment
The LovibondR MultiDirect is a microprocessor controlled photometer with ergonomically designed keypad, large graphic display and waterproof sample chamber and casing. It can operate as a bench top photometer using mains power, and is supplied with rechargeable batteries for portable use. With 6 LED light sources the Multi Direct can measure at peak absorbances for many different methods, ensuring result accuracy and reliability for many applications.
The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.