- Recent add item(s)
-
Lovibond COD Photometer Complete Set 1 × 1.778$×
-
Lovibond TC-135S Thermostatically Controlled Incubators with Standard Door (for BOD-OxiDirect) 1 × 3.445$×
Subtotal: 5.223$
Subtotal: 5.223$
Price 197$ excl.VAT
In StockThis water resistant conductivity meter is the result of customer requests for accurate, affordable process monitoring with low maintenance.
HI 983307 -02 is supplied with a direct 2-pin probe and 2 m (6.6′) cable with a ½” thread for flow-thru mounting. The probe has a temperature sensor to automatically compensate against temperature changes from 5 to 50°C (41 to 122°F) with a β of 2% per degree.
In the measurement mode, a red LED will warn the user in the event the reading is outside of the alarm interval. A front trimmer allows manual calibration at 1 point. The electrical circuitry is tightly sealed inside the water resistant enclosure. This meter can be installed anywhere quickly and easily with the casings molded eye. The casing has been specially designed to sit out of the way and will not roll off a table. The 12 VDC power supply allows continuous monitoring over extended periods of time.
Specification :
| Range | 0.00 to 9.99 mS/cm | |
| Resolution | 0.01 mS/cm | |
| Accuracy | ±2% F.S. | |
| Calibration | manual, 1 point through trimmer | |
| Calibration Solution | HI 70039 | |
| Temperature Compensation | automatic, 5 to 50°C (41 to 122°F) with ß=2%/°C | |
| Setpoint | 0.70 to 3.50 mS/cm | |
| Alarm | red LED blinks when measured value differs from set point more than ±0.20 mS/cm | |
| Probe | HI 7632/2 with 2 m (6.6′) cable and ½” thread (included) | |
| Power Supply | 12 Vdc power adapter (included) | |
| Environment | 0 to 50°C (32 to 122°F); RH max 100% | |
| Dimensions | 86 x 110 x 43 mm (3.4 x 4.3 x 1.7″) | |
| Weight | 215 g (7.6 oz.) |
The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.
| 220 to 240V | |
| ±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) | |
| 600mm | |
| 2 to 40°C, steps of 0.1°C | |
| CE | |
| 441 x 513 x 702mm | |
| LED | |
| 0.1°C |
| 50Hz | |
| 702mm | |
| 39kg | |
| 2 to 40 °C | |
| 135L | |
| 220 to 240V, 50 Hz | |
| 4 internal sockets | |
| 600mm |
| Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
| Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
| Wavelength Accuracy: | ± 1 nm |
| Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
| Photometric Resolution: | 0.01 A |
| Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
| Auto-Off: | 10 minutes after last keypress |
| Display: | LCD (back-light upon keypress) |
| Storage: | automatic; 16 data sets with time and date stamp |
| Interface: | Infrared interface for data transfer |
| Time: | Real time and date |
| Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
| Dimensions: | 155 x 75 x 35 mm |
| Weight: | 250 grams (including batteries) |
| Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
| Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
| Compliance: | CE |
| Warranty: | 2 years |
| Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
The compact TB 210 IR (formerly the TurbiCheck infrared) turbidity meter is designed to allow fast, precise on site or laboratory measurements. The unit measures scattered light at 90 ° angle as stipulated in ISO 7027.
Measuring in the range 0-1100 NTU, the unit is suitable for various applications including drinking water, waste water, process and pool water testing. The infrared light source allows for measurement of coloured and colourless samples.
A simple keypad layout and range selection button ensures further ease of use. Up to 16 results can be stored and reviewed with time and date. The instrument is supplied in a robust carry case with all necessary accessories, and a set of calibration standards.