- Recent add item(s)
-
Lovibond SpectroDirect Photometer 1 × 4.000$×
-
HI9812-5 MULTIPARAMETER PH/EC/TDS/°C - EC TO1990 ΜS/CM 1 × 3.136.000$×
- ×
Subtotal: 3.143.889$
Subtotal: 3.143.889$
Price 15$ excl.VAT
In StockThe TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.
SKU RE-511052BT
Dimension 0
Weight 0.0000
Manufacturer Lovibond
Measurement Range 0.01 – 6 mg/L
Other Function No
Sensor Output Interface No
Power Supply No Need
Resolution No
Water resistance No
Data logger N/A
Accuracy No
220 to 240V | |
±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) | |
600mm | |
2 to 40°C, steps of 0.1°C | |
CE | |
441 x 513 x 702mm | |
LED | |
0.1°C |
50Hz | |
702mm | |
39kg | |
2 to 40 °C | |
135L | |
220 to 240V, 50 Hz | |
4 internal sockets | |
600mm |
Product Type: Test KitBrand: TintometerProduct Line: LovibondClass: CHECKIT Comparator Test KitGrade: Chlorine (DPD)Range: 0 – 2 mg/l Cl2Increments: 0, 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, 1.0, 1.1, 1.2, 1.3, 1.4, 1.6, 1.8, 2.0Accuracy: ±5% (Full Scale)Includes: CHECKIT® Comparator in a sturdy plastic case, CHECKIT® Disc(s), 3 cells & 1 stirring rod, reagents, warranty information, instruction manual
Display | Graphic Display | ||
Interfaces | Infra red interface for test data transfer (via IRiM) RJ45 socket for internal updates |
||
Optics | LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber. Wavelength specifications of interference filters: 430 nm Δ λ = 5 nm 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm 580 nm Δ λ = 5 nm 610 nm Δ λ = 6 nm 660 nm Δ λ = 5 nm |
||
Wavelength Accuracy | ± 1nm | ||
Photometric Accuracy | 2% full scale (at 20 ° C to 25 ° C) | ||
Photometric Resolution | 0.005 A | ||
Operation | Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper | ||
Power Supply | 4 x AA batteries; operating time 26 hours continuous or 3500 tests | ||
Auto Off | approx 20 minutes after last keypress with audible signal | ||
Dimensions | Unit 210 x 95 x 45 mm Carry case 395 x 295 x 106 mm |
||
Unit Weight | 450g | ||
Ambient Conditions | 5-40 ° C, 30-90% rel humidity (non condensing) | ||
Memory Capacity | 1000 data sets with time, date, sample ID | ||
Conformity | CE |