220 to 240V ±°C specified for stirred 500mL water sample. For BOD (T=20°C ±0.5°C) 600mm 2 to 40°C, steps of 0.1°C CE 441 x 513 x 702mm LED 0.1°C 50Hz 702mm 39kg 2 to 40 °C 135L 220 to 240V, 50 Hz 4 internal sockets 600mm ລາຄາ 3.445$ ບໍ່ລວມອາກອນ -
Product Type:ColorimeterBrand:TintometerProduct Line:LovibondClass:Chlorine, pH, Cyanuric AcidRange:0.01 – 6.0 mg/l, 0.1 – 10 mg/l Cl2, 6.5 – 8.4 pH and 0 – 160 mg/l Cyanuric AcidIncludes:Instrument in carrying case, 4 Micro batteries (AAA), 3 Round vials (Glass) 24mm ∅ with lids, Tablet reagents for each parameter, Crushing / Stirring Rod, Guarantee sheet, Certificate (COC), Instruction manual
Instrument: Double wavelength, automatic wavelength selection, direct reading colorimeter Light Source: LEDs, interference fiters (IF) and photosensor in transparent cell chamber.
Wavelength specification of the IF:
530 nm Δ λ = 5 nm
560 nm Δ λ = 5 nmWavelength Accuracy: ± 1 nm Photometric Accuracy: 3% Full Scale (T = 20°-25°C) Photometric Resolution: 0.01 A Power Supply: 4 x AAA (LR 03) Batteries
Lifetime: approximately 17 hours or 5,000 testsAuto-Off: 10 minutes after last keypress Display: LCD (back-light upon keypress) Storage: automatic; 16 data sets with time and date stamp Interface: Infrared interface for data transfer Time: Real time and date Calibration: Supplied factory calibrated.
User calibration is possible.
Reset to factory calibration is possible.Dimensions: 155 x 75 x 35 mm Weight: 250 grams (including batteries) Ambient Conditions: Temperature: 5-40°C
Relative humidity: 30-90% (non-condensing)Waterproof: IP 68 (1 hour at 0.1 meter); floats Compliance: CE Warranty: 2 years Includes: Instrument in carrying case
4 Micro batteries (AAA)
3 Round vials (Glass) with lids
Tablet Reagents for each reagent
Crushing/Stirring Rod
Guarantee sheet
Certificate (COC)
Instruction manuaລາຄາ 1.223$ ບໍ່ລວມອາກອນ -
Display Graphic Display Interfaces Infra red interface for test data transfer (via IRiM)
RJ45 socket for internal updatesOptics LEDs, Interference Filters (IF) and photo sensor in transparent sample chamber.
Wavelength specifications of interference filters:
430 nm Δ λ = 5 nm
530 nm Δ λ = 5 nm
560 nm Δ λ = 5 nm
580 nm Δ λ = 5 nm
610 nm Δ λ = 6 nm
660 nm Δ λ = 5 nmWavelength Accuracy ± 1nm Photometric Accuracy 2% full scale (at 20 ° C to 25 ° C) Photometric Resolution 0.005 A Operation Acid and solvent resistant touch sensitive keypad; audible feedback via integrated beeper Power Supply 4 x AA batteries; operating time 26 hours continuous or 3500 tests Auto Off approx 20 minutes after last keypress with audible signal Dimensions Unit 210 x 95 x 45 mm
Carry case 395 x 295 x 106 mmUnit Weight 450g Ambient Conditions 5-40 ° C, 30-90% rel humidity (non condensing) Memory Capacity 1000 data sets with time, date, sample ID Conformity CE ລາຄາ 1.887$ ບໍ່ລວມອາກອນ -
-
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : Noລາຄາ 78$ ບໍ່ລວມອາກອນ -