The TB 300 IR (formerly TurbiDirect) is an easy-to-use auto ranging turbidity unit designed for the laboratory or portable use. It has an infra red light source and 90 ° detection anlge which conforms to ISO 7027.
The instrument measures from 0 to 1100 NTU and can store up to 1000 data sets with time, date and sample ID. Results can be recalled at any time, and can be downloaded to a PC with the supplied cable.
The large graphic display ensures results are easy to interpret. Instructions during analysis can also be displayed.
The unit is supplied with a set of calibration check standards for further result accuracy.
Product Type:Colorimeter
Brand:Tintometer
Product Line:Lovibond
Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
Wavelength Accuracy: | ± 1 nm |
Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
Photometric Resolution: | 0.01 A |
Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
Auto-Off: | 10 minutes after last keypress |
Display: | LCD (back-light upon keypress) |
Storage: | automatic; 16 data sets with time and date stamp |
Interface: | Infrared interface for data transfer |
Time: | Real time and date |
Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
Dimensions: | 155 x 75 x 35 mm |
Weight: | 250 grams (including batteries) |
Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
Compliance: | CE |
Warranty: | 2 years |
Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
Instrument: | double wavelength, automatic wavelength selection, direct reading colorimeter |
Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
Wavelength Accuracy: | ± 1 nm |
Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
Photometric Resolution: | 0.01 A |
Power Supply: | 4 x AA Batteries Lifetime: approximately 53 hours or 15,000 tests |
Auto-Off: | automatic switch-off |
Display: | LCD (back-light upon keypress) |
Storage: | internal ring memory for 16 data sets |
Interface: | Infrared interface for data transfer |
Time: | Real time and date |
Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
Dimensions: | 190 x 110 x 55 mm |
Weight: | 455 grams (including batteries) |
Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
Compliance: | CE |
Includes: | Instrument in carrying case 4 Micro batteries (AA) 3 Round vials (Glass) with lids Liquid Reagents for each parameter Guarantee sheet Certificate (COC) Instruction manual |
TECHNICAL DATA | |
Product Code | L028 89 402 – L028 62 102 |
Optics | LED’s, interference filters (IF) and photo sensor in transparent sample chamber. Depending on the version, up to 3 different interference filters are used. Wavelength specifications of interference filters: 430 nm wavelength = 5 nm 530 nm wavelength = 5 nm 560 nm wavelength = 5 nm 580 nm wavelength = 5 nm 610 nm wavelength = 6 nm 660 nm wavelength = 5 nm |
Wavelength accuracy | approx. 1 nm |
Photometric Accuracy | 3% FS (T = 20 – 25°C) |
Photometric Resolution | 0.01 A |
Power Supply | 4 batteries (AA), capacity approx. 53 hours or 15 000 tests (continuous operation without display lighting) |
Auto-Off | automatic switch off |
Display | backlit LCD (on key press) |
Storage | internal ring memory for 16 data sets |
Interface | infrared interface for test data transfer to IRiM |
Additional feature | real time clock and date |
Calibration | Factory calibration and user calibration. Rest to factory calibration possible. |
Dimensions | 190 x 110 x 55 mm (L X W X H) |
Weight | approx. 450 g – basic unit |
Environmental Conditions | Temperature: 5 – 40°C
Rel. Humidity: 30 – 90 % (non-condensing) |
HI83300 is a compact, multiparameter photometer for use in the lab or in the field. The meter is one of the most advanced photometers available with a innovative optical design that utilizes a reference detector and focusing lens to eliminate errors from changes in the light source and from imperfections in the glass cuvette. This meter has 60 different programmed methods measuring 37 key water quality parameters and also offers an absorbance measurement mode for performance verification and for users that would like to develop their own concentration versus absorbance curves.