- Recent add item(s)
- ×
-
Lovibond TB-210IR Turbidity Meter 1 × 1.000$×
-
Lovibond MD600 MultiDirect 1 × 1.887$×
- ×
Subtotal: 3.043$
Subtotal: 3.043$
Price 10.867.000$ excl.VATSale 9.998.000$ excl.VAT
HI 931100 is an ion-selective meter that uses a sodium electrode to read the salt (NaCl) content of a solution. This powerful instrument has four ranges, capable of measuring concentrations from 0.150 g/L to 300 g/L.
HI 931100 auto ranges from sample to sample over an extremely broad range without the need for recalibration.
A separate temperature probe, HI 7662, provides temperature readings from -20 to 120°C.
NaCl : 0.150 to 1.500 g/L NaCl 1.50 to 15.00 g/L NaCl 15.0 to 150.0 g/L NaCl 150 to 300 g/L NaCl
°C : -20.o to 120.0ºC (-4.0 to 248.0ºF)
Resolution NaCl : 0.001 g/L NaCl 0.01 g/L NaCl 0.1 g/L NaCl 1 g/L NaCl
°C : 0.1°C (0.1ºF)
Accuracy : (@20°C) NaCl ±5% of reading (NaCl)
°C : ±0.2°C (±0.4ºF) (excluding probe error)
Calibration : automatic, one or two point at 0.30 g/L (HI 7085), 3.00 g/L (HI 7083), 30.0 g/L (HI 7081)
Temperature Compensation : fixed at 25°C (77°F)
Electrode : FC 300B glass body sodium ion electrode with BNC connector and 1 m (3.3’) cable (not included)
Temperature Probe : HI 7662 stainless steel temperature probe with 1 m (3.3’) cable (not included)
Input Impedance: 1012 Ohm
Battery Type / Life : 1.5V AAA (3) / approx. 200 hours of continuous use
Environment : 0 to 50°C (32 to 122°F); RH max 100%
Dimensions : 185 x 72 x 36 mm (7.3 x 2.8 x 1.4’’)
Weight : 300 g (10.6 oz.)
SKU: RE-511222BT
Dimension: 0
Weight: 0.0000
Manufacturer: Lovibond
Measurement Range : 0.01 – 6 mg/L
Other Function : No
Sensor Output Interface : No
Power Supply : No Need
Resolution : No
Water resistance : No
Data logger : N/A
Accuracy : No
The compact TB 210 IR (formerly the TurbiCheck infrared) turbidity meter is designed to allow fast, precise on site or laboratory measurements. The unit measures scattered light at 90 ° angle as stipulated in ISO 7027.
Measuring in the range 0-1100 NTU, the unit is suitable for various applications including drinking water, waste water, process and pool water testing. The infrared light source allows for measurement of coloured and colourless samples.
A simple keypad layout and range selection button ensures further ease of use. Up to 16 results can be stored and reviewed with time and date. The instrument is supplied in a robust carry case with all necessary accessories, and a set of calibration standards.
Instrument: | Double wavelength, automatic wavelength selection, direct reading colorimeter |
Light Source: | LEDs, interference fiters (IF) and photosensor in transparent cell chamber. Wavelength specification of the IF: 530 nm Δ λ = 5 nm 560 nm Δ λ = 5 nm |
Wavelength Accuracy: | ± 1 nm |
Photometric Accuracy: | 3% Full Scale (T = 20°-25°C) |
Photometric Resolution: | 0.01 A |
Power Supply: | 4 x AAA (LR 03) Batteries Lifetime: approximately 17 hours or 5,000 tests |
Auto-Off: | 10 minutes after last keypress |
Display: | LCD (back-light upon keypress) |
Storage: | automatic; 16 data sets with time and date stamp |
Interface: | Infrared interface for data transfer |
Time: | Real time and date |
Calibration: | Supplied factory calibrated. User calibration is possible. Reset to factory calibration is possible. |
Dimensions: | 155 x 75 x 35 mm |
Weight: | 250 grams (including batteries) |
Ambient Conditions: | Temperature: 5-40°C Relative humidity: 30-90% (non-condensing) |
Waterproof: | IP 68 (1 hour at 0.1 meter); floats |
Compliance: | CE |
Warranty: | 2 years |
Includes: | Instrument in carrying case 4 Micro batteries (AAA) 3 Round vials (Glass) with lids Tablet Reagents for each reagent Crushing/Stirring Rod Guarantee sheet Certificate (COC) Instruction manua |
The LovibondR MultiDirect is a microprocessor controlled photometer with ergonomically designed keypad, large graphic display and waterproof sample chamber and casing. It can operate as a bench top photometer using mains power, and is supplied with rechargeable batteries for portable use. With 6 LED light sources the Multi Direct can measure at peak absorbances for many different methods, ensuring result accuracy and reliability for many applications.